Technical
The figures that follow are typical properties achieved in laboratory tests at 20°C and at 50% Relative Humidity:
Fire Resistance BS476: Part 7 Surface spread of flame: Class 2 (indicative)
Slip Resistance Dry >40 low slip potential Method described in BS 7976-2
(typical values for 4-S rubber slider) in accordance with HSE and UKSRG guidelines)
(The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriate maintenance, longer-term wear and/ or surface contaminants (wet or dry).
Textured systems are recommended to meet slip resistance value requirements for wet conditions and/ or surface contaminants (wet or dry) – please contact our Technical Advisors for further details and specifications.
Temperature Resistance: Tolerant up to 60°C
Water Permeability: Nil – Karsten test (impermeable) Vapour Permeability 0.4 gms / m, / 24 hours
Surface Hardness: 180 secs. Koenig Hardness Test
Chemical Resistance: Contact Technical Department
Abrasion Resistance: Taber
Abrader: BS8204-2: Class AR2 50mg loss per 1000 cycles (1kg Load using H17 wheels) Compressive Strength 60 N/mm, (BS6319) Flexural Strength 40 N/mm, (BS6319)
Tensile Strength: 25 N/mm, (BS6319)
Bond Strength Greater than cohesive strength of 25N/mm, concrete. >1.5 MPa.
Electrical Resistance 5 x 10, – 1 x 10, O (to BS 2050)
1.8×10, -1.4×10. 0 (to EN 1081)